AQUAMICRON


Japanese
HOMEWhat is the Karl Fischer Method?AQUAMICRON SeriesTechnical InformationSupport
AQUAMICRON® Series
HOME > AQUAMICRON® Series > Volumetric Reagents
AQUAMICRON® Series
AQUAMICRON® Series
Coulometric Reagents
Example ( Coulometric )
Volumetric Reagents
Example ( Volumetric )
Standard Water Solution
Precautions
Catalog
FAQ
MSDS
Mitsubishi Chemical Analytech Co.,Ltd.

AQUAMICRON Series Example ( Volumetric )
The items required for volumetric titration are a Karl Fischer titrant and methanol or a dehydrated solvent (used to dissolve or disperse the sample).
AQUAMICRON® offers a wide range of products suitable for measuring the moisture content of various samples at every levels. Users can select a solvent that is suitable for the samples based on the following tables.

SS-Z Series (pyridine-free and chloroform-free type)
Product name Use Specification Package
Titrant SS-Z 1mg
[For General-use]
Low moisture content Samples
Titer
0.7-1.2
mgH2O/mL
500mL
Titrant SS-Z 3mg
[For General-use] Titer
2.5-3.5
mgH2O/mL
500mL
Titrant SS-Z 5mg
[For General-use]
High moisture content Samples
Titer
4.5-5.5
mgH2O/mL
500mL
1L
Solvent GEX [For General-use]
Organic solvents, Inorganic chemicals, Agricultural chemicals, Pharmaceuticals, Fertilizers, Detergents, Foodstuffs, etc.
Moisture maximum
0.2mgH2O/mL
500mL
Solvent OLX [For Oils]
Naphtha, Gasolone, Diesel oil, Electrical insulation oil, etc.
Moisture maximum
0.5mgH2O/mL
500mL
Solvent OLII [For Oils and Fats]
Naphtha, Gasolone, Diesel oil, Heavy oil, Electrical insulation oil, Oils and Fats(Hardened oil, Margarine, etc.),etc.
Moisture maximum
0.2mgH2O/mL
500mL
Solvent KTX [For Ketones]
Ketones, Silicone oils, Acetic and other lower carboxylic acids, aldehydes(except acetaldehydes),etc.
Moisture maximum
0.5mgH2O/mL
500mL
Solvent SU [For Sugars]
Sugars, Proteins, Gelatine, Additives, Animal feeds, etc.
Moisture maximum
0.2mgH2O/mL
500mL
When using a moisture vaporization method, mix Solvent GEX with propylene glycol(PG) in a 3:1 ratio (e.g. 90mL of GEX + 30mL of PG).
When using Solvent KTX, it will be needed to make proper adjustments to the parameters. Please contact a manufacturer of the instruments.
An addition of 3g of salicylic acid enables the time for dehydration to get shorter at the first measurment in combined use of 50mL of Solvent SU.
PAGE TOP
SS Series (pyridine type)
Product name Use Specification Package
Titrant SS 1mg
[For General-use]
Low moisture content Samples
Titer
0.7-1.2
mgH2O/mL
500mL
Titrant SS 3mg
[For General-use] Titer
2.5-3.5
mgH2O/mL
500mL
Titrant SS 10mg
[For General-use]
High moisture content Samples
Titer
8-12
mgH2O/mL
500mL
1L
Solvent ML [For General-use]
Organic solvents, Inorganic chemicals, Agricultural chemicals, Pharmaceuticals, Fertilizers, Detergents, Foodstuffs, etc.
Moisture maximum
0.2mgH2O/mL
500mL
Solvent MS [For General-use]
Organic solvents, Inorganic chemicals, Agricultural chemicals, Pharmaceuticals, Fertilizers, Detergents, Foodstuffs, etc.
Moisture maximum
0.2mgH2O/mL
500mL
Solvent CM [For Oils]
Naphtha, Gasolone, Diesel oil, Heavy oil, Electrical insulation oil, Oils and Fats(Hardened oil, Margarine, etc.),etc.
Moisture maximum
0.3mgH2O/mL
500mL
Solvent CP [For Ketones]
Ketones, Silicone oils, Acetic and other lower carboxylic acids, aldehydes(except acetaldehydes),Anilines, etc.
Moisture maximum
0.5mgH2O/mL
500mL
Solvent PP [For Aldehydes]
Acetaldehydes, propionaldehydes, Butyraldehydes, etc.
Moisture maximum
0.2mgH2O/mL
500mL
Solvent PE [For Ketones]
Ketones, Silicone oils, Acetic and other lower carboxylic acids, aldehydes(except acetaldehydes),Anilines, etc.
Moisture maximum
mgH2O/mL
500mL
Solvent FM [For Sugars]
Sugars, Proteins, Gelatine, Additives, Animal feeds, etc.
Moisture maximum
0.2mgH2O/mL
500mL
Solvent ME [For Vaporizer]
Gaseous samples, Nitrogen, etc.
Moisture maximum
mgH2O/mL
500mL
When using a moisture vaporization method, mix Solvent MS with propylene glycol(PG) in a 3:1 ratio (e.g. 90mL of MS + 30mL of PG).
An addition of 3g of salicylic acid enables the time for dehydration to get shorter at the first measurment in combined use of 50mL of Solvent FM.
PAGE TOP